Superseded , Reaffirmed Standard
Historical

ASTM D3824-95(2000)

Standard Test Methods for Continuous Measurement of Oxides of Nitrogen in the Ambient or Workplace Atmosphere by the Chemiluminescent Method

Summary

1.1 These test methods cover procedures for the continuous determination of total nitrogen dioxide (NO2) and nitric oxide (NO) as NOx, or nitric oxide (NO) alone or nitrogen dioxide (NO2) alone, in the ranges shown in the following table:

Range of Concentration
Gas Ambient AtmosphereWorkplace Atmosphere
g/m3 (ppm) (Note 1)mg/m3 (ppm) (NOTE 1)
NO 10 to 600 (0.01 to 0.5) 0.6 to 30 (0.5 to 25)
(NO + NO2) = NOx20 to 1000 (0.01 to 0.05)1 to 50 (0.5 to 25)
NO220 to 1000 (0.01 to 0.5) 1 to 50 (0.5 to 25)

Note 1--Approximate range: 25oC and 101.3 kPa (1 atm).

1.2 The test methods are based on the chemiluminescent reaction between nitric oxide and ozone.

1.3This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific precautionary statements, see Section 9.

Technical characteristics

Publisher American Society for Testing and Materials (ASTM International)
Publication Date 01/01/1995
Confirmation Date 01/01/2000
Collection
Page Count 13
Themes Workplace atmospheres
EAN ---
ISBN ---
Weight (in grams) ---