Superseded , Reaffirmed Standard
Historical

ASTM D5481-96(2001) (R1996)

Standard Test Method for Measuring Apparent Viscosity at High-Temperature and High-Shear Rate by Multicell Capillary Viscometer

Summary

1.1 This test method covers the laboratory determination of high-temperature high-shear (HTHS) viscosity of engine oils at a temperature of 150°C using a multicell capillary viscometer containing pressure, temperature, and timing instrumentation. The shear rate for this test method corresponds to an apparent shear rate at the wall of 1.4 million reciprocal seconds (1.4 10 6 s1). This shear rate has been found to decrease the discrepancy between this test method and other high-temperature high-shear test methods3 used for engine oil specifications. Viscosities are determined directly from calibrations that have been established with Newtonian oils with viscosities from 2 to 5 mPa·s at 150°C.

1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Technical characteristics

Publisher American Society for Testing and Materials (ASTM International)
Publication Date 04/10/1996
Confirmation Date 04/10/1996
Collection
Page Count 5
Themes Lubricants, industrial oils and related products
EAN ---
ISBN ---
Weight (in grams) ---