Withdrawn Standard
Most Recent

ASTM F1662-16

Standard Test Method for Verifying the Specified Dielectric Withstand Voltage and Determining the Dielectric Breakdown Voltage of a Membrane Switch or Printed Electronic Device (Withdrawn 2023)

Summary

1.1 This test method covers the verification of a specified dielectric withstand voltage or dielectric breakdown voltage of a membrane switch or printed electronic device.


Significance and Use:

4.1 Dielectric withstand voltage testing is useful for design verification, quality control of materials, and workmanship.

4.2 This test method is used to verify that the membrane switch or printed electronic device can operate safely at its rated voltage, and withstand momentary overpotentials due to switching, surges and other similar electrical phenomena.

4.3 Specific areas of testing are, but not limited to:

4.3.1 Conductor/dielectric/conductor crossing point,

4.3.2 Close proximity of conductors, and

4.3.3 Any other conductive surface such as shielding or metal backing panel.

4.4 Dielectric withstand voltage testing may be destructive and units that have been tested should be considered unreliable for future use.

4.5 Testing using ac voltage may be useful for switches intended for control circuits powered by ac voltages.


Notes

Revision with Title Change

Technical characteristics

Publisher American Society for Testing and Materials (ASTM International)
Publication Date 05/01/2016
Cancellation Date 11/29/2023
Collection
Page Count 2
Themes Switches
EAN ---
ISBN ---
Weight (in grams) ---