Superseded Standard
Historical

DIN EN 1434-3:2009-01

Heat meters - Part 3: Data exchange and interfaces; English version EN 1434-3:2008

Summary

This European standard applies to heat meters, that is to instruments intended for measuring the heat which, in a heat-exchange circuit, is absorbed or given up by a liquid called the energy-conveying liquid. The meter indicates heat in legal units. Electrical safety requirements are not covered by this standard. Part 3 specifies the data exchange between a meter and a read out device (POINT / POINT communication). For these applications using the optical readout head, the EN 62056-21 protocol is recommended. For direct or remote local readout of a single or a few meters via a battery driven readout device, the physical layer of EN13757-6 (local bus) is recommended. For bigger networks with up to 250 meters, a master unit with AC mains supply according to EN 13757-2 is necessary to control the M-Bus. For these applications the physical and link layer of EN 13757-2 and the application layer of EN 13757-3 is required. For wireless meter communications, EN 13757-4 describes several alternatives of walk/drive-by readout via a mobile station or by using stationary receivers or a network, Both unidirectionally and bidirectionally transmitting meters are supported by this standard.

Notes

À remplacer par DIN EN 1434-3 (2015-05).

Technical characteristics

Publisher Deutsche Institut für Normung e.V. (DIN)
Publication Date 01/01/2009
Cancellation Date 02/01/2016
Page Count 34
EAN ---
ISBN ---
Weight (in grams) ---