Superseded
Draft standard
Historical
DIN EN 4608-001:2018-12
Aerospace series - Cable, electrical, fire resistant - Single and twisted multicore assembly, screened (braided) and jacketed - Operating temperatures between -65 °C and 260 °C - Part 001: Technical specification; German and English version FprEN 4608-001:2018
Summary
This document specifies the required characteristics and test procedures for fire resistant or fire proof electrical cables for use in aircraft electrical systems. They shall be operated at a rated AC voltage of 600 VAC, a frequency of maximum 2000 Hz and a long term temperature of up to 260 °C (ambient temperature plus temperatures rise in conductor). These cables shall also maintain a specific dielectric strength when they are subjected to a flame of 1100 °C after five minutes (fire resistant) or 15 minutes (fire proof) exposure.
Notes
Prévu pour remplacer DIN EN 4608-001 (2008-05).
Technical characteristics
| Publisher | Deutsche Institut für Normung e.V. (DIN) |
| Publication Date | 12/01/2018 |
| Page Count | 29 |
| EAN | --- |
| ISBN | --- |
| Weight (in grams) | --- |
No products.
Previous versions
01/12/2018
Superseded
Historical
01/05/2008
Superseded
Historical