Superseded Draft standard
Historical

DIN EN 4838-005:2017-12

Aerospace series - Arc fault circuit breakers, single-pole, temperature compensated, rated current 3 A to 25 A - 115 V a.c. 400 Hz Constant Frequency - Part 005: With polarized signal contact - Product standard; German and English version FprEN 4838-005:2017

Summary

This European Standard specifies the required characteristics for single-pole, arc fault circuit breakers rated currents from 3 A to 25 A, switching capacity 65 In, for use in aircraft electrical systems. Their operating temperatures are between -40 °C to 85 °C at a maximum altitude of Z = 15000 m. The thermal protection is temperature compensated and operates between -55 °C and 125 °C. These circuit breaker are operated by a push-pull type single pushbutton (actuator), with delayed action 'trip-free' tripping. They will continue to function up to the short-circuit current.

Technical characteristics

Publisher Deutsche Institut für Normung e.V. (DIN)
Publication Date 12/01/2017
Page Count 26
EAN ---
ISBN ---
Weight (in grams) ---
No products.