DIN EN ISO 3679:2015-06
Determination of flash no-flash and flash point - Rapid equilibrium closed cup method (ISO 3679:2015); German version EN ISO 3679:2015
Summary
This International Standard specifies procedures for flash point tests, within the temperature range of -30 °C to 300 °C, for paints, including water-borne paints, varnishes, binders for paints and varnishes, adhesives, solvents, petroleum, and related products. The procedures are used to determine, whether a product will or will not flash at a specified temperature (flash/no-flash Procedure A) or the flash point of a sample (Procedure B). When used in conjunction with the flash detector, this International Standard is also suitable to determine the flash point of fatty acid methyl esters (FAME).
Technical characteristics
| Publisher | Deutsche Institut für Normung e.V. (DIN) |
| Publication Date | 06/01/2015 |
| Page Count | 30 |
| EAN | --- |
| ISBN | --- |
| Weight (in grams) | --- |