Water quality - Determination of aluminium - Spectrometric method using pyrocatechol violett

Summary

Applicable to the analysis of potable waters, ground waters, and lightly polluted surface and sea waters. Determines filterable and acid-soluble aluminium. Includes low range determination up to 100 µg/l Al with 50 mm cells and high range determination up to 500 µg/l Al with 10 mm cells. The limit of detection is 2 µg/l when cells of optical path length 50 mm and a 25 ml test portion are used. Aluminium reacts with pyrocatechol violett at pH = 6 to a coloured complex and the photoometric measurement if this complex allows the determination of the aluminium concentration.

Notes

Pour le(s) document(s) annulé(s) et non remplacé(s) DIN 38406-9 (1989-02) l'éditeur recommande ce document.