IEEE Guide for Generator Ground Protection
Summary
Revision Standard - Inactive-Reserved.
The guide is intended to assist protection engineers in applying relays and relaying schemes for protection against stator ground faults on various generator grounding schemes. The existing guide is outdated due to rapid technology development. Hence, the revised guide includes new stator ground protection principles that have evolved with the use of new technologies in relay designs. Additional application examples are included, and other issues raised by the users are also addressed. The guide is not intended for the selection of generator or ground connection schemes. IEEE Std C37.101-1993/Incorporates IEEE Std C37.101-2006/Cor1:2007.
The guide is intended to assist protection engineers in applying relays and relaying schemes for protection against stator ground faults on various generator grounding schemes. The existing guide is out-dated due to rapid technology development. Hence, the revised guide includes new stator-ground-protection principles that have evolved with the use of new technologies in relay designs. Additional application examples are included, and other issues raised by the users are also addressed. The guide is not intended for the selection of generator or ground connection schemes. The recommendations made pertain to typical generator installations. However, sufficient background information relating to protection requirements, applications, and setting philosophy is given to enable the reader to evaluate the need to select and apply suitable protection for most situations.
The existing guide is needed to cover the new areas due to rapid technology development, and working group will make revision and expansion to clarify those new areas.
The guide is intended to assist protection engineers in applying relays and relaying schemes for protection against stator ground faults on various generator grounding schemes. The existing guide is outdated due to rapid technology development. Hence, the revised guide includes new stator ground protection principles that have evolved with the use of new technologies in relay designs. Additional application examples are included, and other issues raised by the users are also addressed. The guide is not intended for the selection of generator or ground connection schemes. IEEE Std C37.101-1993/Incorporates IEEE Std C37.101-2006/Cor1:2007.
The guide is intended to assist protection engineers in applying relays and relaying schemes for protection against stator ground faults on various generator grounding schemes. The existing guide is out-dated due to rapid technology development. Hence, the revised guide includes new stator-ground-protection principles that have evolved with the use of new technologies in relay designs. Additional application examples are included, and other issues raised by the users are also addressed. The guide is not intended for the selection of generator or ground connection schemes. The recommendations made pertain to typical generator installations. However, sufficient background information relating to protection requirements, applications, and setting philosophy is given to enable the reader to evaluate the need to select and apply suitable protection for most situations.
The existing guide is needed to cover the new areas due to rapid technology development, and working group will make revision and expansion to clarify those new areas.
Notes
Inactive-Reserved
Technical characteristics
Replaces
22/04/1994
Superseded
, Reaffirmed
Historical
Previous versions
15/11/2007
Withdrawn
, Reaffirmed
Most Recent
22/04/1994
Superseded
, Reaffirmed
Historical
31/12/1984
Superseded
, Reaffirmed
Historical