Active
Standard
Most Recent
IEEE C37.30.1:2022
IEEE Standard Requirements for AC High-Voltage Air Switches Rated Above 1000 V
Summary
Revision Standard - Active.
Required ratings, construction requirements, design test requirements, applications, and suggested practices for all high-voltage enclosed indoor and outdoor and non-enclosed indoor and outdoor switches rated above 1000 V are specified. This includes ratings and requirements for such switches as disconnecting, selector, horn-gap, grounding, etc., for manual and power operation, except for interrupter switches, distribution-enclosed single-pole air switches, and distribution cutouts fitted with disconnecting blades.
This standard covers preferred ratings, construction and testing requirements, and application, loading, installation, operation and maintenance guidelines for all high-voltage enclosed and non-enclosed, indoor and outdoor air switches rated in excess of 1000 V. This includes such switch types as disconnect, horn-gap, fault-initiation, and ground for manual or power operation. The following switch types are not covered by this standard: interrupter switches, distribution cutouts fitted with disconnecting blades, and switches used in metal-enclosed and pad-mounted switchgear. This standard also does not apply to load-break separable insulated connectors, circuit breakers, circuit switchers, or reclosers.
Required ratings, construction requirements, design test requirements, applications, and suggested practices for all high-voltage enclosed indoor and outdoor and non-enclosed indoor and outdoor switches rated above 1000 V are specified. This includes ratings and requirements for such switches as disconnecting, selector, horn-gap, grounding, etc., for manual and power operation, except for interrupter switches, distribution-enclosed single-pole air switches, and distribution cutouts fitted with disconnecting blades.
This standard covers preferred ratings, construction and testing requirements, and application, loading, installation, operation and maintenance guidelines for all high-voltage enclosed and non-enclosed, indoor and outdoor air switches rated in excess of 1000 V. This includes such switch types as disconnect, horn-gap, fault-initiation, and ground for manual or power operation. The following switch types are not covered by this standard: interrupter switches, distribution cutouts fitted with disconnecting blades, and switches used in metal-enclosed and pad-mounted switchgear. This standard also does not apply to load-break separable insulated connectors, circuit breakers, circuit switchers, or reclosers.
Notes
Active
Technical characteristics
| Publisher | Institute of Electrical and Electronics Engineers (IEEE) |
| Publication Date | 04/07/2023 |
| Cancellation Date | 04/07/2023 |
| Edition | |
| Page Count | 108 |
| EAN | --- |
| ISBN | --- |
| Weight (in grams) | --- |
| Brochures |
|