IEEE C57.91:1981 (R1991)
IEEE Guide for Loading Mineral-Oil-Immersed Overhead and Pad-Mounted Distribution Transformers Rated 500kVA and Less with 65 C or 55 C Average Winding Rise
Summary
New IEEE Standard - Superseded.
General recommendations for loading 65 degrees Centigrade-rise mineral-oil-immersed overhead and pad-mounted distribution transformers are covered. Recommendations for 55 degrees Centigrade-rise transformers are included because a substantial percentage of these transformers are still in service. The recommendations are based on winding hottest-spot calculations only. Other factors that may limit the permissible load to lower values are listed. A method to establish winding temperature and loss of life by nomographs is given.
This guide covers general recommendations for loading 65 "C rise mineral-oilimmersed overhead and pad-mounted distribution transformers described in American National Standards and rated 500 kVA and less. (For transformers rated 501 kVA and larger, see ANSI/IEEE C57.92-1981, [31') Recommendations for 55 "C rise transformers are included in this guide because a substantial percentage of these transformers are still in service.
General recommendations for loading 65 degrees Centigrade-rise mineral-oil-immersed overhead and pad-mounted distribution transformers are covered. Recommendations for 55 degrees Centigrade-rise transformers are included because a substantial percentage of these transformers are still in service. The recommendations are based on winding hottest-spot calculations only. Other factors that may limit the permissible load to lower values are listed. A method to establish winding temperature and loss of life by nomographs is given.
This guide covers general recommendations for loading 65 "C rise mineral-oilimmersed overhead and pad-mounted distribution transformers described in American National Standards and rated 500 kVA and less. (For transformers rated 501 kVA and larger, see ANSI/IEEE C57.92-1981, [31') Recommendations for 55 "C rise transformers are included in this guide because a substantial percentage of these transformers are still in service.
Notes
Superseded
Technical characteristics
| Publisher | Institute of Electrical and Electronics Engineers (IEEE) |
| Publication Date | 07/31/1981 |
| Confirmation Date | 03/21/1991 |
| Edition | |
| Page Count | 26 |
| EAN | --- |
| ISBN | --- |
| Weight (in grams) | --- |