ISO 16889:2022

Hydraulic fluid power — Filters — Multi-pass method for evaluating filtration performance of a filter element

Summary

This document describes the following: — a multi-pass filtration performance test with continuous contaminant injection for hydraulic fluid power filter elements; NOTE 1 For the background interlaboratory study used to verify the test methodology, see Annex D. — a procedure for determining the contaminant capacity, particulate removal and differential pressure characteristics; — a test currently applicable to hydraulic fluid power filter elements that exhibit an average filtration ratio greater than or equal to 75 for particle sizes = 25 µm(c), and a final reservoir gravimetric level of less than 200 mg/L; NOTE 2 It is necessary to determine by validation the range of flow rates and the lower particle size limit that can be used in test facilities. — a test using ISO medium test dust (ISO MTD) contaminant and a test fluid in accordance with Annex A. This document is intended to provide a test procedure that yields reproducible test data for appraising the filtration performance of a hydraulic fluid power filter element without influence of electrostatic charge. This document applies to three test conditions: — test condition 1, with a base upstream gravimetric level of 3 mg/L; — test condition 2, with a base upstream gravimetric level of 10 mg/L; — test condition 3, with a base upstream gravimetric level of 15 mg/L.

Notes

60.60 : Norme internationale publiée

Technical characteristics

Publisher International Organization for Standardization (ISO)
Publication Date 01/25/2022
Edition 3
Page Count 43
EAN ---
ISBN ---
Weight (in grams) ---