Superseded
Rules
Historical
RCC-CW:2017
Rules for design and construction of PWR nuclear civil works
Paper : Without CD-ROM
Paper : Without CD-ROM
Summary
RCC-CW describes the rules for designing, building and testing civil engineering works in PWR reactors.
It explains the principles and requirements for the safety, serviceability and durability of concrete and metal frame structures, based on Eurocode design principles (European standards for the structural design of construction works) combined with specific measures for safety-class buildings.
The code is produced as part of the RCC-CW Subcommittee, which includes all the parties involved in civil engineering works in the nuclear sector: clients, contractors, general and specialized firms, consultancies and inspection offices.
The code covers the following areas relating to the design and construction of civil engineering works that play an important safety role:
geotechnical aspects;
reinforced concrete structures and galleries;
prestressed containments with metal liner;
metal containment and pool liners;
metal frames;
anchors;
concrete cylinder pipes;
containment leak tests.
The RCC-CW code is available as an ETC-C version specifically for EPR projects (European pressurized reactor).
It explains the principles and requirements for the safety, serviceability and durability of concrete and metal frame structures, based on Eurocode design principles (European standards for the structural design of construction works) combined with specific measures for safety-class buildings.
The code is produced as part of the RCC-CW Subcommittee, which includes all the parties involved in civil engineering works in the nuclear sector: clients, contractors, general and specialized firms, consultancies and inspection offices.
The code covers the following areas relating to the design and construction of civil engineering works that play an important safety role:
geotechnical aspects;
reinforced concrete structures and galleries;
prestressed containments with metal liner;
metal containment and pool liners;
metal frames;
anchors;
concrete cylinder pipes;
containment leak tests.
The RCC-CW code is available as an ETC-C version specifically for EPR projects (European pressurized reactor).
Technical characteristics
| Publisher | Association française pour les règles de conception, de construction et de surveillance en exploitation des matériels des chaudières électro-nucléaires (AFCEN) |
| Publication Date | 01/01/2017 |
| Cancellation Date | 01/01/2018 |
| Edition | 2017 |
| Page Count | 0 |
| EAN | --- |
| ISBN | --- |
| Weight (in grams) | --- |
Replaces
01/01/2016
Superseded
Historical
Previous versions
01/01/2025
Active
Most Recent
01/01/2017
Superseded
Historical
01/01/2016
Superseded
Historical
01/01/2015
Superseded
Historical